This page details the cellranger count output structure for Singleplex Universal 3' and 5' Gene Expression (GEX), V(D)J, Antibody Capture (cell surface protein), using a 5' experiment as an example.
Upon completion, the cellranger count pipeline will produce an outs/ directory with a structure similar to the following:
├── config.csv
├── feature_reference.csv
├── filtered_feature_bc_matrix
│ ├── barcodes.tsv.gz
│ ├── features.tsv.gz
│ └── matrix.mtx.gz
├── filtered_feature_bc_matrix.h5
├── per_sample_outs
│ └── gex_fb_vdj_chr21
├── qc_library_metrics.csv
├── qc_report.html
├── qc_sample_metrics.csv
├── raw_cloupe.cloupe
├── raw_feature_bc_matrix
│ ├── barcodes.tsv.gz
│ ├── features.tsv.gz
│ └── matrix.mtx.gz
├── raw_feature_bc_matrix.h5
├── raw_molecule_info.h5
├── unassigned_alignments.bam
├── unassigned_alignments.bam.bai
├── vdj_b
│ ├── all_contig.bam
│ ├── all_contig.bam.bai
│ ├── all_contig.fasta
│ ├── all_contig.fasta.fai
│ ├── all_contig.fastq
│ ├── all_contig_annotations.bed
│ ├── all_contig_annotations.csv
│ └── all_contig_annotations.json
├── vdj_reference
│ ├── fasta
│ └── reference.json
└── vdj_t
├── all_contig.bam
├── all_contig.bam.bai
├── all_contig.fasta
├── all_contig.fasta.fai
├── all_contig.fastq
├── all_contig_annotations.bed
├── all_contig_annotations.csv
└── all_contig_annotations.json
The files included at the top level may include:
config.csv: a duplicate of the input config CSV file.feature_reference.csv: a duplicate of the input Feature Reference CSV file, if provided.filtered_feature_bc_matrix.h5: filtered feature-barcode matrix (containing only barcodes called as cells), concatenated across all samples, in HDF5 format.qc_library_metrics.csv: quality control report in CSV format for the entire experiment.qc_report.html: quality control report in HTML format for the entire experiment.qc_sample_metrics.csv: quality control report in CSV format by sample.raw_cloupe.cloupe: Loupe Browser file containing all samples and all cell-associated barcodes in the experiment.raw_feature_bc_matrix.h5: raw feature-barcode matrix (containing all barcodes) in HDF5 format.raw_molecule_info.h5: information about all molecules in the experiment. This file includes background and cell-associated barcodes from all samples in addition to valid barcodes that were not assigned to a sample.unassigned_alignments.bam: alignments from barcodes not assigned to any sample.unassigned_alignments.bam.bai: alignments from barcodes not assigned to any sample (index). In cases where the reference transcriptome is generated from a genome with very long chromosomes (>512 Mbp), Cell Ranger generates anunassigned_alignments.bam.csiindex file instead.
Continue reading for descriptions of the directories contained within the top-level outputs.
In addition to the HDF5 format listed above, two directories contain the filtered (concatenated across all samples) and raw feature-barcode matrices in Market Exchange (MEX) Format:
└── filtered_feature_bc_matrix
├── barcodes.tsv.gz
├── features.tsv.gz
└── matrix.mtx.gz
...
└── raw_feature_bc_matrix
├── barcodes.tsv.gz
├── features.tsv.gz
└── matrix.mtx.gz
Filtered outputs are provided in the per_sample_outs directory:
└── gex_fb_vdj_chr21
├── aggregate_barcodes.csv
├── analysis
├── metrics_summary.csv
├── sample_alignments.bam
├── sample_alignments.bam.bai
├── sample_cloupe.cloupe
├── sample_filtered_barcodes.csv
├── sample_filtered_feature_bc_matrix
├── sample_filtered_feature_bc_matrix.h5
├── sample_molecule_info.h5
├── sample_raw_feature_bc_matrix
├── sample_raw_feature_bc_matrix.h5
├── vdj_b
├── vdj_t
└── web_summary.html
aggregate_barcodes.csv: shows antibody (and antigen) barcodes that were detected as aggregates with metrics. See this page for more information.analysis: secondary analysis results, including dimensionality reduction, clustering, and differential gene expression.metrics_summary.csv: experimental metrics in CSV format.sample_alignments.bam: Indexed BAM file containing position-sorted reads aligned to the genome and transcriptome, as well as unaligned reads, annotated with barcode information.sample_alignments.bam.bai: Index file for thesample_alignments.bam. In cases where the reference transcriptome is generated from a genome with very long chromosomes (>512 Mbp), Cell Ranger generates asample_alignments.bam.csiindex file instead.sample_cloupe.cloupe: sample-specific Loupe Browser filesample_filtered_barcodes.csv: sample-specific filtered barcodes in CSV format.sample_filtered_feature_bc_matrix: sample-specific filtered feature-barcode matrix in Market Exchange (MEX) Formatsample_filtered_feature_bc_matrix.h5: sample-specific filtered feature-barcode matrix (containing only barcodes called as cells within this sample) in HDF5 format.sample_molecule_info.h5: information about all molecules in the sample. This file includes background and cell-associated barcodes.sample_raw_feature_bc_matrix: sample-specific raw feature-barcode matrix in Market Exchange (MEX) Formatsample_raw_feature_bc_matrix.h5: sample-specific raw feature-barcode matrix (containing all barcodes assigned to this sample) in HDF5 format.vdj_b: folder containing unfiltered 5' V(D)J analysis results for any B cells (cell-associated and background barcodes), described in the Raw Outputs section. This folder is only produced if a VDJ-B (BCR) library is included in the analysis.vdj_t: folder containing unfiltered V(D)J Immune Profiling analysis results for any T cell (cell-associated and background barcodes) expressing alpha-beta chains, described in the Raw Outputs section. This folder is only produced if a VDJ-T (TCR) library is included in the analysis.web_summary.html: sample-specific web summary HTML, a starting point for quality control.
For 5' Immune Profiling data, V(D)J outputs are provided in three or more directories:
├── vdj_b
│ ├── all_contig.bam
│ ├── all_contig.bam.bai
│ ├── all_contig.fasta
│ ├── all_contig.fasta.fai
│ ├── all_contig.fastq
│ ├── all_contig_annotations.bed
│ ├── all_contig_annotations.csv
│ └── all_contig_annotations.json
├── vdj_reference
│ ├── fasta
│ └── reference.json
└── vdj_t
├── all_contig.bam
├── all_contig.bam.bai
├── all_contig.fasta
├── all_contig.fasta.fai
├── all_contig.fastq
├── all_contig_annotations.bed
├── all_contig_annotations.csv
└── all_contig_annotations.json
vdj_b: folder containing unfiltered 5' V(D)J analysis results for any B cells (cell-associated and background barcodes), described in the Raw Outputs section. This folder is only produced if a VDJ-B (BCR) library is included in the analysis.vdj_reference: a copy of the V(D)J reference used in the analysis.vdj_t: folder containing unfiltered V(D)J Immune Profiling analysis results for any T cell (cell-associated and background barcodes) expressing alpha-beta chains, described in the Raw Outputs section. This folder is only produced if a VDJ-T (TCR) library is included in the analysis.