The bcl2fastq
software is available for download and installation on the Illumina support website as an RPM package. An Illumina account is required for download. Please contact Illumina Support at [email protected] if you have questions about bcl2fastq versions, or for help troubleshooting its download and installation.
You must create a sample sheet for bcl2fastq
to correctly embed the names of samples into output FASTQ files. When you plan an experiment, you should know the name of the sample index set used for each sample, which comes from the reagent kit (such as "SI-TT-A1" for dual index or "SI-GA-A1" for single index).
The Illumina Experiment Manager can also be used to create sample sheets for use with bcl2fastq
.
For each sample, enter its lane, sample name, and sample index set into the Illumina bcl2fastq sample sheet. Here is an example using "SI-TT-A1" indices for i7 and index2_workflow_b
i5:
[Data]
Lane,Sample_ID,index,index2
1,s1,GTAACATGCG,AGGTAACACT
For each sample, enter its lane, sample name, and set of four sample indices into the Illumina bcl2fastq sample sheet. Here is an example using "SI-GA-A1" indices:
[Data]
Lane,Sample_ID,index
1,sample1,GGTTTACT
1,sample1,CTAAACGG
1,sample1,TCGGCGTC
1,sample1,AACCGTAA
If you are only running a single sample in a lane, then you can enter a single line with a blank index, although bcl2fastq
will include reads associated with any sample index.
Illumina bcl2fastq
must be called with the correct --use-bases-mask
argument, and other arguments, in order to properly demultiplex and output FASTQs for all the reads in a Chromium library.
In the examples below, ${FLOWCELL_DIR}
is the directory that contains a flow cell's Data/
folder, ${OUTPUT_DIR}
is the directory that you want to output FASTQs to, and ${SAMPLE_SHEET_PATH}
is the path to the sample sheet CSV you created.
For bcl2fastq2 v2.20, these are the most common command line formats for sequencers running RTA 1.18.54 and higher for either dual or single index kits:
- Dual index demultiplexing (edit the file paths for your data):
SAMPLE_SHEET_PATH=/path/to/sample/sheet/csv
OUTPUT_DIR=/path/to/save/outputs
FLOWCELL_DIR=/path/to/input/BCL/files
INTEROP_DIR=./stats
bcl2fastq --use-bases-mask=Y28,I10,I10,Y91 \
--create-fastq-for-index-reads \
--minimum-trimmed-read-length=8 \
--mask-short-adapter-reads=8 \
--ignore-missing-positions \
--ignore-missing-controls \
--ignore-missing-filter \
--ignore-missing-bcls \
-r 6 -w 6 \
-R ${FLOWCELL_DIR} \
--output-dir=${OUTPUT_DIR} \
--interop-dir=${INTEROP_DIR} \
--sample-sheet=${SAMPLE_SHEET_PATH}
- Single index demultiplexing (edit the file paths for your data):
SAMPLE_SHEET_PATH=/path/to/sample/sheet/csv
OUTPUT_DIR=/path/to/save/outputs
FLOWCELL_DIR=/path/to/input/BCL/files
INTEROP_DIR=./stats
bcl2fastq --use-bases-mask=Y26,I8,Y98 \
--create-fastq-for-index-reads \
--minimum-trimmed-read-length=8 \
--mask-short-adapter-reads=8 \
--ignore-missing-positions \
--ignore-missing-controls \
--ignore-missing-filter \
--ignore-missing-bcls \
-r 6 -w 6 \
-R ${FLOWCELL_DIR} \
--output-dir=${OUTPUT_DIR} \
--interop-dir=${INTEROP_DIR} \
--sample-sheet=${SAMPLE_SHEET_PATH}
Omitting extra bases from reads:
If you add extra bases to a sample index read, you will need to account for this in the --use-bases-mask
argument. For example, if you ran a sample index read with nine bases, you will need to truncate the last base in order for Cell Ranger to run correctly.
You can exclude a single base by adding a single n
character to the read argument, or adding n
to exclude all bases after a certain position. See below:
Read | Desired | Actual | Argument |
---|---|---|---|
i7 Index Read (I1) | 8 | 9 | I8n |
A new folder is created (name specified by the --output-dir
flag). This folder contains the FASTQ file sets, statistics, and reports.
A convenient way to test bcl2fastq is by downloading the tiny-BCL-data
example dataset. This dual-indexed iSeq dataset has been selected for its small size (541 MB). The example below is applicable to 3' Single Cell Gene Expression, 5' Immune Profiling, Fixed RNA Profiling, and Visium libraries processed with the TT Set A dual index kit. It should not be used to run downstream pipelines (e.g. cellranger count
).
To follow along:
- Download the iseq-DI.tar file
- Uncompress the tar file by running:
tar -xf /working-directory/iseq-DI.tar.gz
Run bcl2fastq
(remember to customize the /working-directory/
path with the path to your input/output directory):
SAMPLE_SHEET_PATH=/working-directory/bcl2fastq_samplesheet.csv
OUTPUT_DIR=/working-directory/tiny-FASTQs
FLOWCELL_DIR=/working-directory/iseq-DI
INTEROP_DIR=/working-directory/stats
bcl2fastq --use-bases-mask=Y28,I10,I10,Y91 \
--create-fastq-for-index-reads \
--minimum-trimmed-read-length=8 \
--mask-short-adapter-reads=8 \
--ignore-missing-positions \
--ignore-missing-controls \
--ignore-missing-filter \
--ignore-missing-bcls \
-r 6 -w 6 \
-R ${FLOWCELL_DIR} \
--output-dir=${OUTPUT_DIR} \
--interop-dir=${INTEROP_DIR} \
--sample-sheet=${SAMPLE_SHEET_PATH}
A folder called tiny-FASTQs
is created in the working directory. This folder contains your newly created FASTQ files.
tiny-FASTQs/
├── Reports
│ └── html
├── Stats
│ ├── AdapterTrimming.txt
│ ├── ConversionStats.xml
│ ├── DemultiplexingStats.xml
│ ├── DemuxSummaryF1L1.txt
│ ├── FastqSummaryF1L1.txt
│ └── Stats.json
├── iseq-DI_S1_L001_I1_001.fastq.gz
├── iseq-DI_S1_L001_I2_001.fastq.gz
├── iseq-DI_S1_L001_R1_001.fastq.gz
├── iseq-DI_S1_L001_R2_001.fastq.gz
├── Undetermined_S0_L001_I1_001.fastq.gz
├── Undetermined_S0_L001_I2_001.fastq.gz
├── Undetermined_S0_L001_R1_001.fastq.gz
└── Undetermined_S0_L001_R2_001.fastq.gz